高性能シリーズ

Shimadzu 液相種類 USP Agilent Supelco SGE Phenomenex Quadrex Altech
SH-I-1MS 100% dimethyl polysiloxane G1, G2, G38 HP-1ms UI, HP-1ms, DB-1ms UI, DB-1ms, Ultra-1, VF-1ms SPB-1, Equity-1 BP-1 ZB-1, ZB-1ms 007-1 AT-1ms
SH-I-5MS 5% diphenyl /95% dimethyl polysiloxane G27, G36 HP-5ms UI, HP-5ms, HP-5msSV, DB-5, Ultra-2, CP-Sil 8 CB SPB-5, Equity-5 BP-5ms ZB-5, ZB-5msi 007-5 AT-5ms
SH-I-1HT 100% dimethyl polysiloxane − DB-1HT − − ZB-1HTinferno − AT-1ht
SH-I-5HT 5% diphenyl /95% dimethyl polysiloxane − DB-5HT, VF-5HT − HT-5 ZB-5HTinferno − −
SH-I-5Sil MS 1,4-bis(dimethylsiloxy)phenylene dimethyl polysiloxane G27, G36 DB-5ms UI, DB-5ms, VF-5ms SLB-5ms BPX-5 ZB-5MS, ZB-SemiVolatile, ZM-5MS plus 007-5MS −
SH-I-XLB proprietary phase − DB-XLB, VF-Xms − − ZB-MR1, ZB-XLB − −
SH-I-17 50% diphenyl /50% dimethyl polysiloxane G3 HP-17, DB-17, DB-17HT, DB-608 SPB-17 − ZB-50 − −
SH-I-35Sil MS proprietary phase G42 DB-35ms, DB-35ms UI, VF-35ms − BPX35, BPX608 ZB-MR2 − −
SH-I-17Sil MS proprietary phase G17 DB-17ms, VF-17ms − BPX-50 − − −
SH-I-PAH proprietary phase G51 − − − − − −
SH-I-624Sil MS proprietary phase G43 DB-624, VF-624ms, CP-Select 624 CB − BP-624 − − −
SH-I-1301Sil MS silarylene-based cyano G43 VF-1301ms − − − − −

汎用シリーズ

Shimadzu 液相種類 USP Agilent Supelco SGE Phenomenex Quadrex Altech
SH-1 100% dimethyl polysiloxane G1, G2, G38 HP-1, DB-1, CP Sil 5 CB SPB-1 BP-1 ZB-1 007-1 AT-1, EC-1
SH-5 5% diphenyl /95% dimethyl polysiloxane G27, G36 HP-5, DB-5, CP-Sil 8 CB SPB-5 BP-5 ZB-5 007-5 AT-5, EC-5
SH-5MS 5% diphenyl /95% dimethyl polysiloxane G27, G36 HP-5, DB-5, CP-Sil 8 CB SPB-5 BP-5 ZB-5 007-5 AT-5, EC-5
SH-20 20% diphenyl /80% dimethyl polysiloxane G32 − SPB-20 − − 007-20 AT-20, EC-20
SH-35/ SH-35MS 35% diphenyl /65% dimethyl polysiloxane G42 HP-35, DB-35 SPB-35, SPB-608 BPX-35, BPX-608 ZB-35 007-35 AT-35, AT-35ms
SH-50 100% methyl phenyl polysiloxane G3 HP-50+, CP-Sil 24 CB SPB-50 − − 007-17 AT-50
SH-65 65% diphenyl /35% dimethyl polysiloxane − − − − − 007-65HT −
SH-65TG 65% diphenyl /35% dimethyl polysiloxane − − − − − − −
SH-1301 6% cyanopropylphenyl /94% dimethyl polysiloxane G43 DB-1301, CP-1301, VF-1301ms − − − 007-1301 AT-1301
SH-624 6% cyanopropylphenyl /94% dimethyl polysiloxane G43 HP-624, DB-624, DB-624 UI, VF-624ms SPB-624 BP-624 ZB-624 007-624 AT-624
SH-1701 14% cyanopropylphenyl /86% dimethyl polysiloxane G46 DB-1701P, DB-1701, CP Sil 19 CB, VF-1701ms, VF-1701 Pesticides SPB-1701 BP-10 ZB-1701, ZB-1701P 007-1701 AT-1701
SH-200/ SH-200MS Trifluoropropylmethyl polysiloxane G6 DB-210, DB-200, VF-200ms − − − − AT-210
SH-225 50% cyanopropylmethyl /50% phenylmethyl polysiloxane G7, G19 DB-225, CP-Sil 43 CB SPB-225 BP-225 − 007-225 AT-225
SH-440 modifiedpolysiloxane (uniquephase) − − − − − − −
SH-502.2 diphenyl / dimethyl polysiloxane − DB-502.2 − − − − −
SH-2330 90% biscyanopropyl /
10% cyanopropylphenyl polysiloxane
(Non-bonded)
G5,G8, G48 VF-23ms SP-2330, SP-2331, SP-2380 BPX-70 − 007-23 AT-Silar90
SH-2560 biscyanopropyl / polysiloxane G5 HP-88, CP-Sil88 SP-2560 − − − −
SH-Wax Polyethylene glycol G16, G20, G39 DB-Wax − BP-20 ZB-Wax 007-CW AT-WAXms, EC-WAX
SH-PolarWax Polyethylene glycol G16, G20, G39 HP-Innowax, CP-Wax 52 CB, VF-WAX MS Supelcowax-10 − ZB-Wax Plus − AT-WAX,EC-WAX

アプリケーション専用カラム

Shimadzu 液相種類 USP Agilent Supelco SGE Phenomenex Quadrex Altech
SH-1614 Ideal for analysis of PBDE − − − − − − −
SH-OPP2 Ideal for analysis of organophosphorus pesticides − − − − − − −
SH-CLP/ SH-CLP II Ideal for analysis of organochlorine pesticides − DB-CLP1 / DB-CLP2 − − − − −
SH-VMS Ideal for analysis of volatile organic pollutants − − − − − − −
SH-Volatil Amin Ideal for analysis of volatile amines − CP-Volamine − − − − −
SH-PCB Dedicated to PCBs analysis − − − − − − −
SH-VRX Ideal for analysis of volatile organic pollutants − − − − − − −
SH-FAME Ideal for analysis of FAMEs G16 Select FAME Omegawax − − − AT-AquaWax, AT-FAME
SH-BAC Plus 1/ SH-BAC Plus 2 Ideal for analysis of alcohol compounds in blood − DB-ALC1 / DB-ALC2 − − ZB-BAC-1 / ZB-BAC-2 − −
SH-5 Amine/ SH-35 Amine Ideal for analysis of amines − − − − − − −
SH-PolarD Ideal for analysis of free acid G25, G35 HP-FFAP, DB-FFAP, VF-DA, CP-Wax 58 CB, CP-FFAP CB Nukol BP-21 ZB-FFAP − AT-AquaWax- DA, AT-1000, EC-1000
SH-PolarX Ideal for analysis of amines − CAM,CP-Wax 51 for Amines Carbowax Amine − − − AT-CAM
SH-PolarWAX MS Ideal for analyses of food, flavor, fragrance, industrial chemical and solvent     − − − − AT-WAXms

PLOTカラム

Shimadzu 液相種類 USP Agilent Supelco SGE Phenomenex Quadrex Altech
SH-Alumina BOND/Na2SO4 Aluminum oxide with Na2SO4 deactivation − GS-ALUMINA, CP-Al2O3/Na2SO4 Alumina sulfate PLOT − − − AT-Alumina
SH-Alumina BOND/KCl Aluminum oxide with KCl deactivation − GS-Alumina KCl, HP-PLOT Al2O3 KCl, CP-Al2O3/KCl Alumina chloride PLOT − − − −
SH-Msieve 5A Molecular Sieve 5A − HP-PLOT Molesieve, CP-Molsieve 5A Mol Sieve 5A PLOT − − PLT-5A AT-Mole Sieve
SH-Q-BOND 100% divinylbenzene porous polymer − HP-PLOT Q, CP-PoraPLOT Q, CP-PoraBOND Q Supel-Q PLOT − − − AT-Q
SH-U-BOND Divinylbenzene ethylene glycol / dimethylacrylate porous polymer − HP-PLOT U, CP-PoraPLOT U, CP-PoraBOND U − − − − −

金属カラム

Shimadzu 液相種類 USP Agilent Supelco SGE Phenomenex Quadrex Altech
SH-MetalX-1 100% dimethyl polysiloxane G1, G2, G38 HP-1, DB-1, CP-Sil 5 CB SPB-1 BP1 ZB-1 007-1 AT-1, EC-1
SH-MetalX-1HT SimDist 100% dimethyl polysiloxane − CP-SimDist UltiMetal, DB-HT SimDis ProSteel   − ZB-1X SimDist − −
SH-MetalX-5 5% diphenyl / 95% dimethyl polysiloxane G27, G36 HP-5, DB-5,CP-Sil 8 CB SPB-5 BP5 ZB-5 007-5 EC-5, AT-5
SH-MetalX-1701 non-disclosure G46 DB-1701P, DB-1701, CP-Sil 19 CB, VF-1701ms, VF-1701 Pesticides Equity-1701 BP10 ZB-1701, ZB-1701P 007-1701 AT-1701
SH-MetalX-WAX polyethylene glycol G16, G20, G39 HP-INNOWax, CP-Wax 52 CB, VF-WAX MS Supelcowax-10 − ZB-WAXplus − AT-WAX
SH-MetalX Biodiesel TG non-disclosure − − MET-Biodiesel − − − −