論文リスト2002
当社SPMに関する論文リスト(2002年)です。
著者 | タイトル | 雑誌名 | 巻 | ページ |
CHEN Yun-Xia LIU Wei-Min |
Preparation and Characterization of Nano Au/Al2O3 Composite Thin Films [Chinese] | CHINESE JOURNAL OF INORGANIC CHEMISTRY | 18 | 233-237 |
Hayama Masayo Miyasaka Takehiro Mochizuki Seiichi Asahara Hiroko Tsujioka Katsuhiko Kohori Fukashi Sakai Kiyotaka Jinbo Yoichi Yoshida Masashi |
Visualization of distribution of endotoxin trapped in an endotoxin-blocking filtratioin membrane | Journal of membrane science | 5412 | 1-9 |
Chen, Y. Liu, W. |
Preparation and tribological properties of sol-gel zirconia thin films stabilized with ceria | Materials Letters | 55 | 407-413 |
Goto, M. Honda, F. Uemura, M. |
Extremely low coefficient of friction of diamond sliding against Ag thin films on Si(1 1 1) surface under ultrahigh vacuum condition | Wear | 252 | 777-786 |
Huang, L.. Y. Zhao, J. W. Xu, K. W. Lu, J. |
A new method for evaluating the scratch resistance of diamond-like carbon films by the nano-scratch technique | Diamond and Related Materials | 11 | 1454-1459 |
Kamiya Natsumi Kagi Hiroyuki Notsu Kenji Tsuno Hiroshi Akagi Tasuku |
Inhibiting effects of trace amounts of Lanthanum ion on the dissolution of calcite: a comparative study on calcium carbonete polymorphs | Chemistry letters | 31 | 890-891 |
Liu, W. Chen, Y. Ye, C. Zhang, P. |
Preparation and characterization of doped sol-gel zirconia films | Ceramics International | 28 | 349-354 |
Lu, J. Xu, T. Zhang, P. Yang, S. Qi, S. Xue, Q. |
Effect of C+ implantation on the structure and tribological properties of three metal/SiO2 systems | Thin Solid Films | 416 | 153-159 |
Matsubara Seijiro Yamamoto Hiromasa Oshima Kochiro Mouri Emiko Matsuoka Hideki |
Fabrication of nano-structure by diels-alder reaction | Chemistry letters | 31 | 886-887 |
Sekiguchi, H. Arakawa, H. Okajima, T. Ikai, A. |
Non-destructive force measurement in liquid using atomic force microscope | Applied Surface Science | 188 | 489-492 |
Sree, U. Yamamoto, Y. Deore, B. Shiigi, H. Nagaoka, T. |
Characterisation of polypyrrole nano-films for membrane-based sensors | Synthetic Metals | 131 | 161-165 |
Tamaki, J. Naruo, C. Yamamoto, Y. Matsuoka, M. |
Sensing properties to dilute chlorine gas of indium oxide based thin film sensors prepared by electron beam evaporation | Sensors and Actuators B: Chemical | 83 | 190-194 |
Yuan, K. Radhakrishnan, K. |
Growth and characterization of compositionally graded InGaP layers on GaAs substrate by solid-source molecular beam epitaxy | Journal of Crystal Growth | 243 | 288-294 |
Zhang, W. Liu, W. Wang, C. |
Tribological behavior of sol-gel TiO2 films on glass | Wear | 253 | 377-384 |
Zhang, W. Liu, W. Wang, C. |
Characterization and tribological investigation of sol-gel Al2O3 and doped Al2O3 films | Journal of the European Ceramic Society | 22 | 2869-2876 |
王 栄光 森弘尚希 徳田太郎 木戸光夫 |
各種金属表面での水滴による濡れ性の原子間力顕微鏡(AFM)による評価※1 | 日本金属学会誌 | 66 | 808-815 |